Exclusive representatives for Colombia of Hakel
Czech Republic company manufacturer of Surge Protection Devices SPD
DPS Class I
Impulse discharge current for class I test (10/350) 50 KA per pole. Consisting of multiple non-exhausting spark gaps. For TNS or TNC systems, voltages 150, 208, 220, 380, 440 y 480 V.
Line G
HLA 50-XXX / Y+0



Line
HS 50 / HS 55





DPS Class I + II
Impulse discharge current for class I test (10/350) 25 KA per pole. It consists of high energy double varistors for better discharge ability and a gas discharge tube connected in series, which ensures zero leakage current through the conductor.
For TNS or TNC systems, voltages 150, 208, 220 y 275 VAC.

Line G
HLSA 25 G-XXX / Y+0



Line SPC 25 DS 3 + 1
TO 275 VAC

Impulse discharge current for class I test (10/350) 12,5 KA per pole. It consists of high energy double varistors for better discharge ability and a gas discharge tube connected in series, which ensures zero leakage current through the conductor
For TNS or TNC systems, voltages 150, 208, 220 y 275 VAC.
Line G
HLSA 12,5-XXX / Y+1



DPS Class II
Nominal discharge current for class II test (8/20) 15 KA or 20 KA. Consisting of high energy varistors in some cases also in combination with gas discharge tube, which ensures zero leakage current in the PE conductor.
For TNS or TNC systems, voltages 150, 208, 220 y 275 VAC.
Line G
HSA-XXX / Y+1. CLASS II + III



Line PIIIM



DPS Class III
Nominal discharge current for class III test (8/20) 3 KA. Consisting of high energy varistors.
For single-phase and two-phase systems, voltages 12, 24, 48, 120, 220 AC o DC.

Line
ZS-1DSM-XXX

Surge Protector for Photovoltaics Systems
Impulse discharge current for class I test (10/350) 6,5 KA per pole and nominal discharge current for class II test (8/20) 15 KA. It consists of high energy double varistors for better discharge ability and a gas discharge tube connected in series, which ensures zero leakage current through the conductor
For systems of 600, 800 and 1000 VDC.
Class I+II


Nominal discharge current for class II test (8/20) 15 KA. It consists consisting of high energy varistors
For systems of 600, 800 and 1000 VDC.
Class II


High Power Gas Discharge Tube (Spark Gaps)
HGS 100 and HGS 100 EB (100 KA) are a separating high power gas discharge tubes intended for equi- potential bonding of an installation parts of buildings, which are not interconnected. In case of origin of p.d. (potential difference) between those parts, the high-power gas discharge tube ignites and interconnects both parts for a transient time (typical value of internal resistance at startup of HGS100 is 0,001 ÷ 0,002 Ω).
Recommended installation is inside of the buildings, outdoors, in the damp rooms as well as in the subterraneous areas.
HGS 100 EX